← Back to Products
Contact for Inquiry
Class II A2 Biological Safety Cabinet
Balanced protection for routine microbiological work. Class II A2 cabinets protect personnel, products and the environment with stable inflow and vertical downflow. Approximately 70% of filtered air is recirculated within the cabinet while 30% is exhausted through the top outlet, combining containment with energy-efficient operation.
70%filtered air recirculation
30%filtered air exhaust
3-waypersonnel, product and environmental protection
Advantages
- Three-way protection for personnel, products and the surrounding environment.
- 70% filtered-air recirculation and 30% top exhaust support efficient routine operation.
- ULPA filtration reaches at least 99.9995% efficiency at 0.12µm.
- Stable inflow and vertical downflow help maintain the protective air barrier.
- A 200mm operating opening balances access with containment performance.
- The fully finished SS304 work area is durable and easy to clean.
- Integrated LED and UV lighting supports visibility and work-zone decontamination.
- Service fixtures and a spare socket support common laboratory procedures.
- Universal wheels with adjustable leveling feet simplify positioning and installation.
Model Comparison
| Model | YZ-BSC-1000IIA2 | YZ-BSC-1300IIA2 | YZ-BSC-1600IIA2 | YZ-BSC-1800IIA2 |
|---|---|---|---|---|
| Nominal Size | 1 meter (3') | 1.3 meter (4') | 1.6 meter (5') | 1.8 meter (6') |
| Filtration Efficiency | ULPA: ≥99.9995%, @0.12µm | |||
| Downflow Velocity | 0.35 m/s (68.88fpm) | 0.33 m/s (64.94fpm) | ||
| Inflow Velocity | 0.55 m/s (108.24fpm) | 0.53 m/s (104.30fpm) | ||
| Airflow System | 70% air recirculation, 30% air exhaust | |||
| Noise | 58~65 dB(A) | |||
| Vibration | ≤5 µm (center of table top) | |||
| Power Supply | AC220V, 1Φ, 50Hz | |||
| Opening Height | 200mm | |||
| Personnel Protection | A. Total colony in impaction sampler ≤10CFU./time B. Total colony in slot sampler ≤5CFU./time | |||
| Product Protection | Total colony in culture dish ≤5CFU./time | |||
| Cross-contamination Protection | Total colony in culture dish ≤2CFU./time | |||
| Max Consumption (with spare socket) | 1.65 kVA | 1.75 kVA | 1.85 kVA | 1.85 kVA |
| Rated Power (without spare socket) | 0.33 kVA | 0.43 kVA | 0.53 kVA | 0.53 kVA |
| Weight | 260 kg | 300 kg | 360 kg | 400 kg |
| Work Dimension (W1×D1×H1) | 1004×630×630 mm (39.5″×24.8″×24.8″) | 1304×630×630 mm (51.3″×24.8″×24.8″) | 1604×630×630 mm (63.1″×24.8″×24.8″) | 1804×630×630 mm (71.0″×24.8″×24.8″) |
| Overall Dimension (W×D×H) | 1200×795×2050 mm (47.2″×31.3″×80.7″) | 1500×795×2050 mm (59.1″×31.3″×80.7″) | 1800×795×2050 mm (70.9″×31.3″×80.7″) | 2000×795×2050 mm (78.7″×31.3″×80.7″) |
| Size and Qty. of Light | LED 24.5 W × 1 | LED 31 W × 1 | LED 36 W × 1 | LED 36 W × 1 |
| Size and Qty. of UV Light | 18 W × 1 | 30 W × 1 | 36 W × 1 | 36 W × 1 |
| Lumin. | ≥900 Lx | |||
| Cabinet Materials | High-grade steel and lacquered in ivory | |||
| Working Area Materials | SS304 fully finished | |||
| Air Direction | Top out | |||